Name of Article: Static Mate

| Part Number | RS-10N |
|---|---|
| Featuer | This blower newtralizes static electricity of charged object by spraying air, which is ionized by means of AC high-voltage corona discharge, to the charged object by using fan. |
| Use Application | For electrostatic damage prevention on electronics production and assembly lines. |
| For prevention of electrostatically-induced instrument error in computer rooms and precision measurement labs. | |
| For preventing dusts and dirts from adhering to plastic parts. | |
| For safeguarding against static electricity on high-speed printing lines. | |
| For preventing dust build-up on optical instruments or precision devices. | |
| For guarding against static electricity during processing of materials such as fabrics. |
6 Features of Ionizer
1.Automatic Ion Balancing System
Self-control within ±10VU'
2.Extreme Ionbalance Alarm
Alarm sounds if ionic imbalance exceeds the blower's regulating capacity.
3.Cleaning Alert
A warning light flashes and a buzzer sounds if ion quantity drops due to dirt electrodes or a clogged air filter.
4.Easy-to-clean electrodes
Removable front panel
5.Simple electrode replacement
Uses one-side pin connectors.
6. Unscented ozone-free method
Less than 0.003ppm
SPECIFICATIONS
| Input Power Source | AC100V~115V |
|---|---|
| Frequency | 50/60Hz |
| Output Power Source | AC4.1KV(AC100V) |
| Power Consumption | 26VA(AC100V) |
| Fuse | 0.5A(normal meltdown) |
| Air Capacity | 1.6m3/min~2.6m3/min(50Hz) |
| Ozon Volume | 0.003PPM or less |
| (10mm from nozzle) | |
| Scope of Static | (±)10V and below |
| Eliminator Control | 0~40°C |
| Ambient Temperature | MAX65%RH |
| Ambient Humidity Weight | 2.7kg |
| Outside Dimension (Main Body) | 160(W)×149(D)×285(H)mm |
| Nozzle | 110(W)×60(H) oval mm |
Discharge Capability
| Item | RS-10 | Remarks | ||
|---|---|---|---|---|
| Ion Balance | (V) | ±10 or less | Built-in ion balance controller | |
| Discharge Time (S) +1,000V→+100V | Test Location | 30cm | 1 | +1,000V→+100V Discharge Time |
| 60cm | 2 | |||
| 90cm | 3 | |||
| 120cm | 5 | |||
| Discharge Time (S) +1,000V→+100V | Test Location | 30cm | 1 | +1,000V→+100V(RS-10) Discharge Time |
| 60cm | 3 | |||
| 90cm | 5 | |||
| 120cm | 7 | |||
| Air Velocity(m/s) | Test Location | 30cm | 4.2 | |
| 60cm | 2.9 | |||
| 90cm | 2 | |||
| 120cm | 1.4 | |||
Air Speed and DistributionU'Distance, Air Speed and Dispersal Characteristics

Prohibited
This product is not explosion-proof. Do not use it under hazardous conditions such as the presence of large aquantities of solvents or powders.
Caution
If used where humidity is greater than 65%RH, the ion balance controller may deviate from its normal range.
Remarks
Grounding wire of 3 prong plug should be grounded (B or D)